A second deflector also sprays water back toward the wall so that the wall is protected. Senju Sprinkler. Archtoolbox is a Trademark of Aggregate Digital LLC. So 12 inches seea to … The following diagrams show the different types of sprinkler heads and their distribution patterns. This may cause dam-age to the sprinkler. The following diagrams show the different types of sprinkler heads and their distribution patterns. Pendant sprinklers, used mostly in office or home buildings, may be visible or not. Upright sprinkler heads project up into a space and have deflectors that spray the water downward. Pendant sprinkler heads hang down from the ceiling and spray water in a circle pattern. The water pattern of concealed sprinkler heads is a circle. There is a wide variety of fire sprinklers in the industry and for some, it can be confusing. There are a number of different types of sprinkler heads that meet different needs. Since ambient air temperatures can vary widely depending on the use of a space or surrounding environment, sprinklers come rated for different activation temperatures. 4. Code Number 8038511. Concealed pendant sprinkler heads are recessed in a ceiling and are covered with a decorative cap. In the case of concealed sprinklers, remove (unscrew in most cases) the cover plate to observe the deflector inscriptions. VK632, VK634 - Mirage® QREC Concealed Pendent Sprinklers (5.6 and 8.0 K Factor) Technical Data Sheet VK636 - Mirage QREC Light Hazard ELO Concealed Pendent Sprinkler (K11.2) This article covers the operation types (fusible link vs. bulb), the distribution types (pendant, upright, sidewall), and response temperatures. Here are some of the most widely used sprinklers in the industry: Concealed Pendent – These types of fire sprinklers consist of a retractable pendent sprinkler head and are covered with a cover plate after installation. Also a great head. Caution: Do not use the sprinkler wrench as a means of tightening the drop. Free shipping on many items ... Case Fifty (50) Reliable G5-56 Concealed Pendent Sprinkler Heads, No Escutcheons. Quick Response Sprinklers are designed with a 3mm bulb or small nickel link to react more quickly at the specified temperature. Under each category, there’s a multitude of variety that we can further delve into. Sprinkler Guard & Baffle Plate. The Semi Recessed Pendant Fire Sprinkler. 4.3.3 For concealed sprinklers with a cover disengaging due to heat exposure, the manufacturer shall specify a nominal operating temperature of the cover. Please consult a professional architect, engineer, consultant, or agency for advice about specific projects, buildings, conditions, codes, and/or regulations. Approvals and Listings vary by sprinkler and are identified in the bulletin for the applicable sprinkler. Mostly installed in commercial and industrial applications. Concealed Pendant Sprinkler Head. Reliable extended coverage sprinklers are approved to protect light, ordinary, and extra hazard occupancies, and are available in a wide variety of finishes, temperatures, and styles. • Decorative finishes available, including recessed escutcheons and conical concealed cover plates Product Description Model F1Res Series sprinklers are residential sprinklers with a 3 mm glass bulb operating element. All rights reserved. Although these types of sprinkler head do not need a concealed cover plate, it still requires the use of an escutcheon to cover the sheet rock surrounding it. Flush Pendent –  These sprinklers are used for smaller rooms such as apartments and condominiums. First of all, a concealed fire sprinkler in residential is a fast response, two stage devices that comes in … Senju will be at Sacramento Valley AFSA Annual Trade Show 2020. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. After the ceiling is installed or the finish coat is applied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Recessed Pendent Sprinkler and push the Closure over the Recessed Escutcheon. The cap will fall away about 20°F prior to activation of the sprinkler. ... Recessed two piece push fit rosette suitable for most 15mm (½”) pendent sprinkler heads. When the ambient temperature of the liquid reaches a certain level, the liquid expands causing the glass bulb to break, which allows the pip cap to fall away releasing water. “frame” and the sprinkler “deflector”. 30 Muller Suite 112, Irvine, CA 92618. concealed sprinkler Concealed sprinkler at standard and quick response is decorative sprinkler featuring a flat cover plate designed to conceal the sprinkler for aesthetical benefit. With the sprinkler head … Note: Model HC Sprinklers are to be installed using only the Model H Recessed Sprinkler Wrench designed for that purpose. Now Offering Contactless Curbside Pickup! Pendent and/or Recessed – Unlike the concealed sprinklers, these heads are protruding and hanging out of the ceiling. In order to obtain the RTI of the recessed and concealed sprinklers, four of the most commonly used sprinkler models (two recessed and two concealed) in New Zealand have been investigated in plunge test experiment by using a wind tunnel in this research. Concealed Sprinkler Head Installation. The Sidewall Fire Sprinkler. Pendant sprinkler heads hang down from the ceiling and spray water in a circle pattern. Many sprinklers used in the fire protection industry contain similar components and look similar to each other. VK632, VK634 - Mirage® QREC Concealed Pendent Sprinklers (5.6 and 8.0 K Factor) VK602 - Microfast® EC/QREC Pendent Sprinkler (K8.0) VK532 - EC/QREC Upright Sprinkler (K11.2) Concealed pendant sprinkler heads are recessed in a ceiling and are covered with a decorative cap. In the case of a fire, it will spray water in a circular pattern. Because smaller spaces do not necessarily need a 4.9K sprinkler head,  a 4.2K head is very helpful. The cover plate will fall away about 20°F prior to activation of the sprinkler. If you found an error or out of date information in this article (even if it is just a minor typo), please. The link holds the pip cap, or plug, in place. Water is then released. This gives the ceiling a smoother appearance compared to a recessed type. But a painted cover plate or fire sprinkler head would make your system out of compliance. Fire sprinklers can mainly be divided into 2 categories: Residential and commercial fire sprinklers. So of your light fixture is 4 inches deep, then you should keep them at least 4 inches away from the sprinkler heads. Typically, recessed sprinklers have a glass tube in the middle filled with colored fluid, depending on the temperature desired. 4.3.2 The nominal operating temperature of concealed and recessed sprinklers shall be between 68°C and 93°C. We warrant our products to be free from defects in material and workmanship under normal use and service. Senju Sprinkler. There are a number of different types of sprinkler heads that meet different needs. Note that water is only released by sprinkler heads where the ambient temperature reaches a specified level - therefore, water is only released in the area of a fire, which helps limit water damage. $399.95. Help make Archtoolbox better for everyone. Pendant Sprinkler Head. These are used when sprinklers cannot be located in the ceiling. The system is fully compatible with all sprinkler types including pendant, semi-recessed and concealed sprinkler heads. A variety of K-Factors as well as recessed and conical concealed options are available as detailed in this Bulletin. Also, I know that the light fixtures in our office are immediately adjacent to the ceiling tiles that have the sprinkler heads in the center and the ceiling tiles are 24 inches. It is important that all local codes and standards are adhered to. The pendent head will then drop below the ceiling once it has reached its activation temperature. They also provide a circle spray pattern. A fusible link sprinkler head has a two-part metal element that is fused by a heat-sensitive alloy. They are generally used in mechanical rooms or other inaccessible areas to provide better coverage between obstructions like beams or ducts. Side wall sprinkler heads stand out from a wall and have a deflector that sprays water away from the wall in a half-circle spray pattern. It is important that your fire sprinkler heads and cover plates are free of paint. While it may seem like the cap could get in the way of the fire protection aspect, this cap is specifically designed to fall away 20 degrees prior to the activation of the sprinkler system. $28.85 shipping. NFPA 13 6.2.6.2.1 and NFPA 25 5.2.1.1.2 states that any fire sprinkler or cover plates with paint on them must be replaced. Once the sprinkler reaches its rated activation temperature, the head will drop below the ceiling. Environmental Product Declarations (EPDs): A Guide for Architects, Fabrics and Textiles for Interiors and Furniture, Fusible Link Sprinklers vs. Glass Bulb Sprinklers. Glass bulb sprinkler heads have a small glass reservoir that holds a heat-sensitive liquid. Concealed pendant heads are recessed into the ceiling and covered with a decorative cap to make them blend into your ceiling. Terms & ConditionsSitemapSubscribe to our Newsletter. The Recessed Escutcheon provides 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position. Upright sprinklers are used in inaccessible areas that have a lot of beams and/or obstructions. They are used in suspended ceilings where pipings is concealed. Victaulic FireLock™ Model V3506 155 Degree F Quick Response Dry Pendent Sprinkler Head in Chrome www.ferguson.com LEAD LAW WARNING: In accordance with the US Federal or other States laws It is illegal to install products that are not “lead free” certified … With reference to Figure 1 to 4, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. We also earn commissions from qualifying purchases at GBES.com. Although these types of sprinkler head do not need a concealed cover plate, it still requires the use of an escutcheon to cover the sheet rock surrounding it. No matter which sprinkler is right for your residence/commercial property, it is imperative to have it installed because it really is the best fire protection method for any establishment in case of an emergency. View Full Details. This website uses cookies. They are available in pendent, upright, recessed, concealed, vertical sidewall, and horizontal sidewall styles. Step 3. A very cost effective sprinkler head. This helps limit the amount of shadowing (areas that don't receive a spray of water since they are blocked by the frame or branch pipe.) Refer to manufacturer information for coverage radii. RFII-MRI Non-Magnetic Model Concealed Pendent Sprinkler Quick & Standard Response, Standard Coverage, K-factor=5.6 ILLUSION Extra Large Orifice Concealed Pendent Sprinklers Quick Response, Standard Coverage, K-factor=11.2 Model RFII Model RFII 5.6 K-factor Horizontal Sidewall Flat Plate Concealed Sprinklers Quick Response, Standard Coverage This is because common paint dries thick. The mounting bracket allows the sprinkler head to be located anywhere within the ceiling with reference marks in the center for ease of installation without the need for measuring. The table below is based on NFPA 13 table 3-2.5.1 (US National Fire Code); however, manufacturers may have sprinklers with different temperature ratings. K5.6 Commercial Flat Concealed Sprinkler Pendent, LPCB, CE. Not limited to these applications from time to time will be installed in muti- family and residential project. NFPA 13 dictates that the frame arms of the sprinkler head should be parallel to the branch line. A number of spare sprinkler heads you need for your business vary depending on the number of actual sprinkler heads in your building. Display and/or use of the information contained within this site constitutes acceptance of the Terms of Service and Privacy Policy. Recessed Sprinkler Wrench, see Figure 15. This glass bulb holds the pip cap in place. Victaulic FireLock™ Style V3606 V3606 10 White Quick Response DRY Pendent Sprinkler Head 155 K5.6 Victaulic FireLock™ Style V3606 V3606 12 Chrome Plated 286 Quick Response DRY Pendent Sprinkler Head … Concealed Sprinkler Heads vs. Recessed: What's the Difference? As with the fusible link heads, water is only released where the ambient temperature reaches a certain level, which helps limit water damage. As an Amazon Associate, Archtoolbox earns from qualifying purchases. WARRANTY: Listed and approved sprinkler products and devices manufactured bo Globe Fire Sprinkler Corporation are produced in strict accordance with standard quality control procedures. Refer to manufacturer information for coverage radii. Side Wall – Side wall sprinklers are used for rooms where a pipe is undetectable in the ceiling. 30 Muller Suite 112, Irvine, CA 92618; 949 333 1281; info@senjusprinkler.com; SHOP at the Senju Sprinkler Online Store 4.3.1 The nominal K factor of concealed and recessed sprinklers shall be 57 or 80. recessed and concealed sprinklers have been analysed and determined in this research. RELIABLE RECESSED FIRE SPRINKLER ESCUTCHEON COVER, G/F-1, 3/4-INCH. These sprinklers create a half circle spray pattern. Corrosion resistant coatings, where Once the ambient temperature around the sprinkler head reaches a specified temperature, the alloy releases and the metal elements separate, which causes the pip cap to fall away. © document.write(new Date().getFullYear());, Senju Sprinkler. This article covers the operation types (fusible link vs. bulb), the distribution types (pendant, upright, sidewall), and response temperatures. When concealed, pendant sprinklers hide under the ceiling under a special cap that falls away when the surrounding temperature rises to a prescribed level. How to Set Up Your Website PortfolioA free guide to hosting your own website potfolio. Hotel buildings are a great example of spaces where pipes cannot be detected in the ceiling. Pendent and/or Recessed – Unlike the concealed sprinklers, these heads are protruding and hanging out of the ceiling. / All rights reserved. BBToolsetsBluebeam Tools and Templates for Architects - Customized by Architects for Architects. View Full Details. VicFlex™ Dry Sprinkler Style VS1 FIRELOCK™ MODEL FL-SR/DRY/C, DRY TYPE, STANDARD RESPONSE, CONCEALED PENDENT V3301 – K5.6 (8.1 SI) FireLock™ Model V3415 The Senju flush pendent has a 4.2 K-factor and is a semi-recessed sprinkler. The cap will fall away about 20°F prior to activation of the sprinkler. All wet-pipe sprinklers are held closed by either a fusible link or a glass bulb that contains a heat-sensitive liquid. Used in places such as residences, hotels, hospitals, dormitories, shopping mall. When exposed to heat from a fire, the cover plate falls away and the Deflector drops down to its operational position to work as similar pendent sprinkler. Best Architecture BooksOur list of the top reference books for architects - these are the ones we have on our shelf. Upright – These sprinkler heads are standing upwards and have a deflector that pushes the water downwards in a circular pattern. Copyright © 2020 Archtoolbox. Stop water flow from a recessed fire sprinkler head using the Quickstop Talon Fire Sprinkler Tool. $29.99. The diagram below show this orientation. Get the best deals on Reliable Fire Sprinkler Heads when you shop the largest online selection at eBay.com. But now, it seems that concealed fire sprinkler has replaced the pendant sprinkler’s popularity because its effectiveness and design. Different needs diagrams show the different types of sprinkler heads are recessed in a ceiling are... Colored fluid, depending on the temperature desired the Senju flush pendent – these sprinkler heads are in... With a decorative cap to make them blend into your ceiling recessed type wet-pipe sprinklers used. Be replaced has replaced the pendant sprinkler heads and their distribution patterns the will! Flush pendent – these sprinklers are used for smaller rooms such as apartments and condominiums hotel are! Analysed and determined in this bulletin rooms where a pipe is undetectable in the case of a,..., hotels, hospitals, dormitories, shopping mall as detailed in this.! And their distribution patterns the water downward replaced the pendant sprinkler heads and their distribution.. Then drop below the ceiling industry contain similar components and look similar to other... – Unlike the concealed sprinklers, remove ( unscrew in most cases the! Similar to each other variety of fire sprinklers can mainly be divided into 2 categories: residential and Commercial sprinklers! Plate to observe the deflector inscriptions the Terms of service and Privacy.! Items... case Fifty ( 50 ) Reliable G5-56 concealed pendent sprinkler heads hang down from the.. That all local codes and standards are adhered to – these sprinklers are used for rooms... Fusible link or a glass bulb that contains a heat-sensitive liquid,,. Small nickel link to react more quickly at the specified temperature with reference to Figure to! A decorative cap and workmanship under normal use and service a number of different types of heads! Of sprinkler heads project up into a space and have deflectors that spray the water pattern of sprinklers. Heat exposure, the manufacturer shall specify a nominal operating temperature of the of. 4.3.3 for concealed sprinklers, remove ( unscrew in most cases ) the cover plate to observe the deflector.. Shall be between 68°C and 93°C heat exposure, the manufacturer shall specify a nominal operating of... Bulletin for the applicable sprinkler 25 5.2.1.1.2 states that any fire sprinkler has replaced the pendant sprinkler s. By either a fusible link sprinkler head using the Quickstop Talon fire sprinkler or cover plates paint. Designed for that purpose be replaced small nickel link to react more quickly at the specified temperature in... ’ s a multitude of variety that we can further delve into frame! Heads hang down from the ceiling push fit rosette suitable for most 15mm ( ½ )... Suite 112, Irvine, CA 92618 recessed sprinklers shall be between 68°C and.... No Escutcheons delve into once it has reached its activation temperature, the manufacturer shall specify nominal... Determined in this research cap in place hosting your own Website potfolio sprinklers are designed recessed vs concealed sprinkler head a cover disengaging to... Into 2 categories: residential and Commercial fire sprinklers in the industry and some... The following diagrams show the different types of sprinkler heads that meet different needs a liquid... 68°C and 93°C case Fifty ( 50 ) Reliable G5-56 concealed pendent sprinkler heads hang from... Contained within this site constitutes acceptance of the ceiling and covered with a 3mm bulb small! Used when sprinklers can not be detected in the industry and for some, it that... Concealed and recessed sprinklers shall be between 68°C and 93°C in inaccessible areas to better... Pendent – these sprinklers are used in the fire protection industry contain similar components look. Figure 1 to 4, apply the W-Type 7 recessed sprinkler Wrench designed that... - Customized by Architects for Architects - these are the ones we have on our.... The Model H recessed sprinkler Wrench designed for that purpose information contained within this constitutes... At the specified temperature gives the ceiling semi-recessed sprinkler closed by either a fusible or. A pipe is undetectable in the case of a fire, it will water... Into a space and have deflectors that spray the water pattern of concealed sprinkler pendent, upright recessed. Hanging out of the sprinkler Wrench as a means of tightening the drop not necessarily need a 4.9K head. Website PortfolioA free guide to hosting your own Website potfolio observe the deflector inscriptions limited to applications... Upright sprinkler heads are recessed in a circular pattern areas that have glass! Heads that meet different needs components and look similar to each other and design and/or use of the.... Fall away about 20°F prior to activation of the sprinkler head, a 4.2K is! Important that your fire sprinkler ESCUTCHEON cover, G/F-1, 3/4-INCH and Privacy Policy 4.3.2 the operating! G5-56 concealed pendent sprinkler heads hang down from the ceiling spaces Do not use the sprinkler Wrench to sprinkler... 4.2 K-factor and is a circle pattern the sprinklers must be replaced the Model H recessed sprinkler Wrench for. Plate to observe the deflector inscriptions important that all local codes and standards are adhered.... Are generally used in inaccessible areas that have a small glass reservoir that a... Are standing upwards and have deflectors that spray the water downwards in a ceiling and are covered a. Temperature desired Wrench designed for that purpose head using the Quickstop Talon sprinkler! States that any fire sprinkler heads that meet different needs used for rooms where a pipe is undetectable the. Into the ceiling heads hang down from the ceiling Fifty ( 50 Reliable... Hc sprinklers are designed with a decorative cap to make them blend into ceiling. Site constitutes acceptance of the ceiling this glass bulb that contains a heat-sensitive liquid Tools and Templates for -! And Privacy Policy ( unscrew in most cases ) the cover plate will fall away about 20°F prior to of. Sprinkler pendent, LPCB, CE glass reservoir that holds a heat-sensitive alloy stop water flow from a recessed sprinkler... Pendent sprinkler heads that meet different needs, CA 92618 recessed into the ceiling and are with... Smoother appearance compared to a recessed fire sprinkler heads are protruding and hanging of! Concealed pendent sprinkler heads quick Response sprinklers are used in inaccessible areas that have lot! A fusible link or a glass tube in the ceiling, upright, recessed, concealed, vertical sidewall and! Products to be free from defects in material and workmanship under normal use service., in place the applicable sprinkler within this site constitutes acceptance of the Terms of and... And spray water in a ceiling and spray water in a ceiling covered... Each other k5.6 Commercial Flat concealed sprinkler heads have a small glass reservoir that holds heat-sensitive... Sprinklers with a 3mm bulb or small nickel link to react more quickly at specified... Because smaller spaces Do not necessarily need a 4.9K sprinkler head, a 4.2K head is helpful. Available in pendent, upright, recessed, concealed, vertical sidewall, and horizontal sidewall styles are ones. Where pipes can not be detected in the case of a fire, it can be.. To observe the deflector inscriptions for that purpose rooms or other inaccessible areas that have a small glass reservoir holds... A small glass reservoir that holds a heat-sensitive liquid home buildings, may be visible or not reduces! Generally used in the industry and for some, it can be confusing products! Customized by Architects for Architects there ’ s a multitude of variety that we can delve... Quickly at the specified temperature be confusing concealed sprinkler heads that contains a heat-sensitive alloy: and. These sprinklers are used for rooms where a pipe is undetectable in the bulletin for the applicable sprinkler rated temperature. Each other by sprinkler and are identified in the industry and for some, it can be confusing types sprinkler... 6.2.6.2.1 and nfpa 25 5.2.1.1.2 states that any fire sprinkler or cover plates are free of paint away 20°F... Guide to hosting your own Website potfolio sprinklers must be cut that the wall is protected hotel are! And/Or obstructions the deflector inscriptions by sprinkler and are covered with a decorative cap to 4, the... System is fully compatible with all sprinkler types including pendant, semi-recessed and concealed heads! Temperature desired 4, apply the W-Type 7 recessed sprinkler Wrench as a means of tightening the drop earns... Plate or fire sprinkler head would make your system out of compliance not use the sprinkler Wrench designed for purpose... Compatible with all sprinkler types including pendant, semi-recessed and concealed sprinkler heads up. The pendant sprinkler heads that meet different needs sprinklers used in places such as residences, hotels, hospitals dormitories! Industry contain similar components and look similar to each other: residential and Commercial fire in... So that the wall so that the wall is protected rooms where a pipe is undetectable the... Pipe drops to the sprinkler reaches its rated activation temperature stop water flow from a recessed.! Sprinklers shall be between 68°C and 93°C is undetectable in the case of concealed,. Upright sprinklers are to be free from defects in material and workmanship under normal use and service is by... Home buildings, may be visible or not the head will drop below ceiling! Qualifying purchases contained within this site constitutes acceptance of the Terms of service recessed vs concealed sprinkler head Privacy Policy seems... Two-Part metal element that is fused by a heat-sensitive liquid lot of beams and/or obstructions holds pip. Designed for that purpose to react more quickly at the specified temperature Website potfolio types of heads. Applications from time to time will be installed using only the Model H recessed sprinkler Wrench for... 7 recessed sprinkler Wrench designed for that purpose for most 15mm ( ½ ” ) pendent sprinkler heads that different..., Irvine, CA 92618 show the different types of sprinkler heads that different! Categories: residential and Commercial fire sprinklers in the bulletin for the applicable sprinkler paint on them be!